Smart HVAC Controller IR Wall Mounted: (HVAC-SIRM-WM-SR) (HVAC-SIRM-WM-LR)
This Module is for wall mount Split AC. It is programmed as per the make of the AC and the module will control the AC via Infrared signal (same as the remote) no hard wiring. The temperature and ON/OFF can be set from the cloud. The module has a built-in temperature sensor. All local controls are over ridded. This module communicates with the Smart communication.
FEATURES: Measures the Room Temperature | Set Temperature control from Cloud ON/OFF Control from Cloud | Compressor running.
Smart HVAC Controller IR Ceiling Mounted: (HVAC-SIRM-CM-SR) (HVAC-SIRM-CM-LR)
This module is for controlling DX System without Filter Monitoring. This module communicates with the Smart communication console with Gateway through wireless communication The module collects the data from all the sensors and the status of the AHU and transmits to the cloud at regular intervals (10 Min). This data can be used for analytics like knowing the performance of AHU. The module communicates with the Smart communication console with Gateway through wireless communication.
The unit switches ON/OFF the system as per the timing set in the cloud. The set temperature is also programmed from the cloud
as per the set temperature the module will control the cooling
THE FOLLOWING DATA IS COLLECTED:
Supply Air Temperature | Return Air Temperature |Unit Running time in min
compressor running time in min | delta T
FEATURES: Temperature sensor for Supply Air | Temperature sensor for
Return Air ON/OFF Control from Cloud | Set Temperature Control
Smart HVAC Controller DX1 Module without Filter Monitoring (HVAC-SDX1-WM-SR)
(HVAC-SDX1-WM-LR)
This module is for controlling DX System without Filter Monitoring. This module communicates with the Smart communication console with Gateway through wireless communication The module collects the data from all the sensors and the status of the AHU and transmits to the cloud at regular intervals (10 Min). This data can be used for analytics like knowing the performance of AHU. The module communicates with the Smart communication console with Gateway through wireless communication.
The unit switches ON/OFF the system as per the timing set in the cloud. The set temperature is also programmed from the cloud
as per the set temperature the module will control the cooling
THE FOLLOWING DATA IS COLLECTED:
Supply Air Temperature | Return Air Temperature |Unit Running time in min
compressor running time in min | delta T
FEATURES: Temperature sensor for Supply Air | Temperature sensor for Return Air ON/OFF Control from Cloud | Set Temperature Control
Smart HVAC Controller DX2 Module with Filter Monitoring (HVAC-SDX2-WM-SR)
(HVAC-SDX2-WM-LR)
This module is for controlling DX System without Filter Monitoring. This module communicates with the Smart communication console with Gateway through wireless communication The module collects the data from all the sensors and the status of the AHU and transmits to the cloud at regular intervals (10 Min). This data can be used for analytics like knowing the performance of AHU. This module communicates with Smart communication.
The unit switches ON/OFF the system as per the timing set in the cloud. The set temperature is also programmed from the cloud.
As per the SET temperature, the module will control the cooling
THE FOLLOWING DATA IS COLLECTED:
Supply Air Temperature | Return Air Temperature | Unit Running time in min.
Compressor running time in min delta T Filter monitoring (Pressure drop across Filter in Pascal)
FEATURES: Temperature sensor for Supply Air | Temperature sensor for Return Air ON/OFF Control from
Cloud | Set Temperature Control
Smart HVAC FCU Controller Module (HVAC-SFCU-WM-SR) (HVAC-SFCU-WM-LR)
This module is for controlling FCU System without Filter Monitoring. This module communicates with the Smart
communication console with Gateway through wireless communication
The module collects the data from all the sensors and the status of the FCU and transmits it to the cloud at regular intervals (10 Min). This data can be used for analytics like knowing the performance of FCU
The unit switches ON/OFF the system as per the timing set in the cloud. The set temperature is also programmed from the cloud.
As per the Set temperature, the module will control the cooling
THE FOLLOWING DATA IS COLLECTED:
Supply Air Temperature | Return Air Temperature |
Compressor running time in min | delta T | Filter monitoring (Pressure drop across Filter in Pascal)
FEATURES: Temperature sensor for Supply Air | Temperature sensor for Return Air ON/OFF Control from Cloud | Set Temperature Control
Smart HVAC AHU Controller AX1 Module without Filter Monitoring
This module is for controlling AHU with chilled water supply without filter monitoring. This module communicates with the Smart communication console with Gateway through wireless communication.
The unit switches ON/OFF the system as per the timing set in the cloud. The set temperature is also programmed from the cloud.
As per the SET temperature, the module will control the cooling by giving control output to the Actuator.
The module collects the data from all the sensors and the status of the AHU and transmits it to the cloud at regular intervals (10 Min). This data can be used for analytics like knowing the performance of AHU.
THE FOLLOWING DATA IS COLLECTED:
Supply Air Temperature | Return Air Temperature | Unit Running time in min.
Compressor running time in min | delta T | Filter monitoring (Pressure drop across Filter in Pascal)
FEATURES: Temperature sensor for Supply Air | Temperature sensor for Return Air Temperature sensor for Chilled water supply | Temperature sensor for Chilled Water Return 0 to 10 V D.C output for controlling Actuator | 0 to 10 V D.C Input for Actuator Feedback 0 to 10 V D.C output for controlling VFD | ON & OFF Command for controlling AHU Set Temperature Control | 4 Channel Status Input | I. Unit ON & OFF Status | ii. Unit Trip Status iii. Unit Auto or Manual Status | Fire Signal Input
Smart HVAC AHU Controller AX2 Module with Filter Monitoring (HVAC-SAX2-WM-SR) |
(HVAC-SAX2-WM-LR)
This module is for controlling AHU with chilled water supply without filter monitoring. This module communicates with the Smart
communication console with Gateway through wireless communication.
The unit switches ON/OFF the system as per the timing set in the cloud. The set Temperature is also programmed from the
cloud. As per the SET temperature, the module will control the cooling by giving control output to the Actuator.
The module collects the data from all the sensors and the status of the AHU and transmits it to the cloud at regular
intervals (10 Min). This data can be used for analytics like knowing the performance of AHU.
FEATURES: Temperature sensor for Supply Air | Temperature sensor forReturn Air
Temperature sensor for Chilled water supply | Temperature sensor for Chilled Water Return 0 to 10 V D.C output for
controlling Actuator | 0 to 10 V D.C Input for Actuator Feedback 0 to 10 V D.C output for controlling VFD | ON & OFF Command for controlling
AHU Set Temperature Control | 4 Channel Status Input | i. Unit ON & OFF Status | ii. Unit Trip Status iii. Unit Auto or Manual Status | Fire Signal
Input Filter Monitoring (Pressure drop across Filter in Pascal)
Smart HVAC AHU Controller AX5 Module (HVAC-SAX5-WM-SR) | (HVAC-SAX5-WM-LR)
This module is for controlling AHU with chilled water supply without filter monitoring. This module communicates with the Smart
communication console with Gateway through wireless communication.
The unit switches ON/OFF the system as per the timing set in the cloud. The set temperature is also programmed from the cloud.
As per the set temperature, the module will control the cooling by control output to the Actuator.
The module collects data from all sensors the status of the AHU transmits to the cloud at regular intervals (10min).
This data can be used for analytics like knowing the performance of AHU
FEATURES: Temperature sensor for Supply Air | Temperature sensor for Return Air | Temperature sensor for Chilled water supply Temperature sensor for
Chilled Water Return | 0 to 10 V D.C output for controlling Actuator 0 to 10 VD.C Input for Actuator Feedback | 0 to 10 V D.C output for controlling VFD | ON
& OFF Command for controlling AHU Set Temperature Control | 4 Channel Status Input | I. Unit ON & OFF Status | ii. Unit Trip Status iii. Unit
Auto or Manual Status | Fire Signal Input | Filter Monitoring (Pressure drop across Filter in Pascal)
OPTIONAL ADAPTORS:
RH | Static pressure | Air Flow sensor | Co2 | Return Air Damper control | Fresh Air Damper Control | Dew Point Filter Monitoring (Multichannel) | Temperature Sensor (Multichannel) 0 to 10 VD.C output/Input (Multichannel) | Status Monitoring (Multichannel) | 4 Channel Status | PM Sensor
Smart Terminal VAV System
The System consists of:
I. SINGLE VAV CONTROLLER MODULE(SVCM)
Smart Single VAV Controller is used where one VAV is linked to one Thermostat.
FEATURES
(SVCM) is used where one VAV is linked to 1 Thermostat
RS485 Communication Port-1 No
Temperature Sensor-1No
DC Motor-1No
Wireless Communication LORA-1 No
II. SLAVE VAVCONTROLLER MODULE (SLVCM)
The smart Slave VAV Controller module receives the instructions from the Master VAV controller module and controls the
VAV
FEATURES:
Slave VAV Controller module receives the instructions from the Master VAV Controller module and controls the VAV Slave VAV Controller modules
-10No can be connected to 1 Master VAV Controller Module
RS485 Communication Port-1 No
Temperature Sensor-1No
DC Motor-1No
a) MASTER VAV CONTROLLER MODULE (MVCM)
Smart MVCM collects the instructions from the main controller module to control 01 VAV on its own and to control the
group of SLVCM for opening and closing Of the flap as per the set temperature
FEATURES:
-For 1No Master VAV Controller module slave VAV controller module-09No can be connected and 01No VAV can be directly connected.
-Smart MVCM collects the instructions from the main controller module to control 01 VAV on its own and to control the group of SLVCM for opening and closing of the flap as per the set temperature
-If there are multiple VAVS to be operated on a single thermostat this combination is used.
-The MVCM is got built- temperature sensor with 4M Cable, It can control 01 VAV on its own and 09VAVS through SLVCM RS485 Communication Port -2 No’s
-Temperature Sensor-1No
-DC Motor-1No
b) MAIN CONTROLLER MODULE (MCM)
Smart (MCM) directly communicates with the Smart communication manager console with a gateway through wireless communication LORA. In turn, smart Communication manager console with Gateway is connected to the cloud through GPRS. Similarly, you can also control the temperature from the cloud. Smart communication manager console with Gateway is suitable to interlink 10Nos of MCM for each Smart Communication Console Manager with Gateway.
FEATURES:
-Smart (MCM) directly communicates with the Smart communication manager console with Gateway through wireless communication LORA.
– Smart communication manager console with Gateway is suitable to interlink
-10Nos of MCM for each Smart communication manager with Gateway
-RS485 Communication Port-1No
-Wireless communication LORA-1No
c) THERMOSTAT FOR SINGLE VAV CONTROLLER MODULE (SVCM)
Smart Thermostat is used for connecting it to a single VAV controller module (SVCM)
FEATURES:
-Temperature sensor-1No
-KoB of setting temperature
Smart HVAC HRW Controller Module with Filter Monitoring (HVAC-SHRWM-WM-SR) |
(HVAC-SHRWM-WM-LR)
This module is for controlling HRW System with Filter Monitoring. This module Communicates with the Smart communication manager console with a
Gateway Through Wireless communication.
The module collects the data from all the sensors and the status of the HRW and Transmits it to the cloud at regular intervals (10 Min). This data can be used for Analytics like knowing the performance of HRW
The unit switches ON/OFF the system as per the timing set in the cloud. The set temperature is also programmed from the cloud. As per the SET
temperature, the module will control the cooling.
FEATURES:
ON/OFF Command for controlling HRW
Status Input for: –
I. 0-10V DC Input for Blower Status
ii. HRW Auto or Manual status
iii. HRW ON & OFF Status
Exhaust Air Temperature Before the Wheel | Exhaust Temperature After the wheel
Fresh Air Temperature after the wheel | Outside Air Temperature
0-10V DC Output for controlling of Blower
DP Switch for FA Filter Monitoring (Pressure drop across Filter in Pascal) | Δ T Exhaust Air
Δ T Supply Air | – Unit running time in min
Smart Chiller Plant Monitoring System (HVAC-SCPMS-WM-SR) (HVAC-SCPMS-WM-LR)
This module will give the efficiency of the chiller plant. This module Communicates with the Smart communication console Manager with
Gateway through Wireless communication.
FEATURES:
Chilled water Supply Temperature
Chilled water Return Temperature
KWH consumed.
Running Hours
Supply Pressure
Return Pressure
Other Parameters on Request
Smart Cooling Tower Monitoring System:
This module will give the efficiency of the cooling tower plant. This module Communicates with the Smart communication manager console with
Gateway Through wireless communication.
FEATURES:
Supply water Temperature
Return water Temperature
KWH consumed
Running Hours
Flow rate of water
Cumulative flow
Wet Bulb temperature
Ambient Temp
%RH
Δ T of supply/Return Water
0 to 10 V Output for Control of Fan VFD
Other parameters on request
Smart Chilled Water Pump Monitoring & Control Module (HVAC-SCPMCS-WM-SR) (HVAC-SCPMCS-WM-SR)
This module will monitor & control the chilled water pumps. This module Communicates with the Smart communication manager console with Gateway.
Through wireless communication
FEATURES:
Supply Temperature
Return Temperature KWH
consumed Running Hours
Δ T
Differential pressure (Δ P)
ON/OFF for Secondary Pump with respect to Δ P (Optional VFD control)
Other
parameters on Request This module will monitor & control the chilled water pumps. This module Communicates with the Smart communication manager console with Gateway. Through wireless communication